Standard of Visual Quality for Installed Glazing
This document is offered to assist the end users to stipulate an acceptable visual quality standard for installed glazing.
Using the viewing criteria set out below, if a scratch, mark or blemish is visible to the naked eye, it should be regarded as unacceptable. The unit should be either repaired or replaced.
Glazed units should be clean, free of dirt and residue at the time of inspection.
Single, double and triple glazed glass units should be viewed using the same viewing criteria;
Area of Inspection –
The area to be viewed is the entire surface area of the glazed unit viewed from a standing distance of 1 metre.
It should be noted that multiple people viewing / inspecting the glass may be of differing heights, so the viewing / inspection results may differ.
Viewing Angles –
Glazed units, be they single, double or triple glazed, should be viewed from both sides of the glass (when feasible) at a distance of 1 meter back from the glass and from 3 angles – 45' from the left, 45' from the right and from a 90' angle from the centre of the unit.
For glass that has been repaired, additional viewing criteria should be applied; standing 3 & 5 meters back from the unit being inspected and repeating the viewing angles above (where feasible) checking for hazing or cloudy patches and or distortion.
When viewing glazed units that have been repaired, viewing should be centered on the area of the repair. Please Note – at a 45' angle you may notice natural distortions in the glass.
Lighting –
Inspection should be made under natural daylight, avoiding any glare from direct sunlight as this could obscure your vision. Water or moisture on the glass will also impair visibility. When artificial light plays a part in the 'usual everyday' lighting conditions (wall, recess or up-lighting) this should be taken into account when inspecting the glass.
Imperfections –
Totally enclosed seeds, bubbles or blisters, hairlines or minute embedded particles are occasionally found in flat glass. Although it has been standard practice to disregard such defects, providing that they are neither obtrusive nor bunched together, in today's market, this should really be an acceptance decision for the end user. Definitions of obtrusive or bunched will differ dependent on who is viewing the glass.
Internal Cavity Imperfections –
Double or triple glazed units with marks, smears, finger prints or scratches on any internal surface should be considered unacceptable.
Natural Distortions –
Certain elements of visual distortion are deemed acceptable in glass manufacturing. Glass units that are 'processed', such as toughened glass, go through additional manufacturing processes which can change the visual appearance of the glazing, creating visual distortions in glass that are well documented and accepted as a natural element of processed glass.
Anisotropy (or Strain Pattern) –
Anisotropy is a specific visual effect that can be seen in some toughened glass panels under polarised light. It is caused by the differing layers of 'stress' or tension within the thickness of a toughened glass unit. When polarised light passes through these areas of the glass it can appear as an iridescent or coloured pattern on the surface of the glass.
As polarised light is present within normal daylight Anisotropy may be visually apparent at certain times of day or under certain lighting conditions. This appearance in glass is often more apparent when the glass is viewed indirectly or when glass is installed at right angles to each other.
This visual phenomenon can also be known as a Strain Pattern, Quench Marks or Leopard Spots. Anisotropy is an accepted characteristic of the glass toughening process and is not classed as a glass defect.
Roller Wave –
Roller Wave is a common type of visual distortion that may be visible in toughened glass units. It is caused during the glass toughening process when the heated and slightly molten glass is passed over large rollers whilst it is cooled. As a result, the glass may have a slightly waved finish to the surface.
This does not affect the strength or durability of the toughened glass and is only visually detectable under certain circumstances. As a rule, Roller Wave is not classed as a visual defect in glass.
Newtons Rings (Interference Fringes) –
Newton Rings are the most common example of Interference Fringes in insulating glass as they are often the easiest to see. They are caused when two panes of an insulated glass unit touch each other.
Where the glass units connect you will see a series of concentric fringes that surround the point of contact.
The visual distortion is caused by the delay in light reflection between these two surfaces of glass causing two light waves to combine.
The presence of a Newton Ring in an insulated glass unit may be a result of a narrow spacer bar being used within the insulated glass unit. If the spacer bar used in your I.G.U is too narrow the natural deflection in the glass units may cause the two panes to touch.
Reflections and Refraction –
Visible double reflection can occur under certain lighting aspects / conditions, especially when viewed from an angle. This is an optical phenomenon arising from multiple surface reflections in sealed units.
When viewed under certain light conditions, insulating glass units (double or triple glazed) incorporating clear or tinted flat laminated glass may show a distortion effect caused by reflection on the multiple surfaces of the components of the laminated glass.
Brewster's Fringes – are sometimes seen in glazed units in the form of straight bands of colour. This is due to reflection and refraction when two glasses of similar substance having flat and parallel surfaces are placed close together, such as a double or triple glazed unit. This is most likely to be noticed when looking at the glass indirectly from a bright exterior with the room side comparatively dark.
When a double glazing manufacturer makes units from glass which is extremely flat and parallel, there is a risk of the phenomenon of Brewster's Fringes being present. This situation can apply to glass from any manufacturer in the world since it is a feature related to the physics of light. The presence of Brewster's Fringes is in no way detrimental to the performance of the unit, does not interfere with direct vision and is a reflection effect when viewing the window as a mirror.
Suction Marks on Glass –
When glass is being manufactured and installed rubber suction cups are used to move glass. On occasion, these suction cups can leave rubber residue on the glass surface that can attract moisture. The sucker marks become visible when condensation forms on the glass.
This rubber residue can dissipate over time under normal exposure to the elements, but heavier residue may not dissipate naturally.
Although not seen as a defect in glazing, as sucker marks can be removed very easily with general glass cleaning products, they should be removed immediately after installation as the longer they are present, the harder become to remove. For this reason, sucker marks should be regarded as an unacceptable imperfection caused during installation.
Patterned Glass – The above criteria does not apply to patterned glass as due to the method of manufacture, imperfection such as seeds and bubbles are deemed to be acceptable.
Repaired Glass –
Repaired glass should present no sign of being repaired. Hazing or cloud remaining as a result of repair, swirling scratch or fining marks or distortions to the glass should not be acceptable in the repaired unit.
Advice: Any dispute relating to a standard of glazing is between the supplier and customer. Although you can seek expert advice and or mediation from a number of sources, remember that this is a third-party service, usually chargeable.
Although some organisations may lead you to believe differently, there is no official governing body for the glazing industry. Organisations offering guidance and advice, including ourselves, have no authority and cannot legislate or enforce anything.
The best advice we can give you is to include a standard for the visual quality for installed glazing in your initial purchase, supply or installation agreement. In this way you have stipulated your required standards for your installed glass and had it agreed to by your supplier that will stand up in a court of law.